Uncontrolled movement happens when the cabin with open doors, moves downwards; this movement must be stopped in such a way that the distance between the car floor of the cab and that of the landing floor is not greater than 1200 mm. The free distance between the upper end of the cabin doors and the landing floor must not be less than 1000 mm. Both requests must be satisfied at the same time.
MORIS Italia offers three products designed and developed in compliance with the following directives
- Lift directive 2014/33/UE
- EN81-2:1998, A3:2009
- EN 81-20:2014
- EN 81-50:2014
The HSV and HMSV safety valves are electrically operated control valves for hydraulic lifts. Installed on the distributor block, they allow the oil flow during the up direction and do not allow it in the opposite direction unless the solenoid valve is powered.
HSV: universal valve installed on all distributor block by means of special adapters.
- Model HSV-150-> from 50 to 150 l / min
- Model HSV-440 -> from 151 to 440 l / min